← Back to overview

Study of the Month – November 2026: Standard Tissue-Level Ceramic Implant in the Aesthetic Zone: A Clinical Case

26.11.2026 · 7 min


In the final clinical case of our esthetic implant series, we take a closer look at the standard SDS tissue-level ceramic implant. This clinical case demonstrates the immediate replacement of a compromised maxillary central incisor and highlights how the available anatomy influenced implant selection and positioning.




Key Takeaways
In this clinical case, an intact buccal bone wall and dense palatal bone provided favorable anatomical conditions for the standard SDS tissue-level ceramic implant. Palatal positioning allowed the available bone to be used for primary stability while avoiding unnecessary compression of the buccal bone.

Following extraction of tooth 11, an SDS 1.2_4614 zirconia implant was placed immediately and restored with a non-functional provisional crown. High primary stability was achieved, with an AnyCheck value of 74 and an insertion torque of 75 Ncm.

After six months, the definitive ceramic crown was delivered. Later follow-up showed healthy-appearing peri-implant soft tissues and stable clinical conditions through May 2026.



When is the standard design an option?


The standard SDS tissue-level ceramic implant features a round implant design. In the 4.6 mm implant used in this case, the tulip has a diameter of 6 mm.

In the anterior maxilla, two anatomical conditions are particularly favorable for this design: an intact buccal bone wall and dense palatal bone. When these conditions are present, the implant can be positioned more palatally, using the available palatal bone for primary stability while avoiding unnecessary compression of the buccal bone.

The following clinical case presented exactly these conditions.


Initial situation


The male patient presented with a compromised maxillary right central incisor (FDI 11). The tooth had previously undergone root canal treatment and apical surgery but had developed recurrent discomfort and was no longer considered maintainable.

Preoperative diagnostics included CBCT imaging, intraoral scans, and clinical photography. The main challenge was the location of the affected tooth in the esthetic zone, where preservation of the available hard and soft tissues is essential for the final restorative outcome.

Importantly, the site showed a stable buccal bone wall and dense palatal bone, providing favorable conditions for the standard implant design.


Immediate implant placement


The surgical treatment was performed by Moritz Kneer at the Swiss Biohealth Clinic.

Tooth 11 was completely extracted, cystic tissue was removed, and the socket was carefully curetted. An SDS 1.2_4614 zirconia implant was immediately placed into the extraction socket.

High primary stability was achieved, with an AnyCheck value of 74 and an insertion torque of 75 Ncm. The implant was immediately restored with a non-functional provisional crown.

Early postoperative evaluation showed very good wound healing. Implant stability remained favorable throughout healing, with a later AnyCheck value of 86.


Prosthetic rehabilitation and follow-up


After six months, the patient received the definitive ceramic crown, performed by Dr. Gintare Burian at the Swiss Biohealth Clinic. In the anterior region, particular attention was given to the emergence profile, crown morphology, shade integration, and occlusion.

The initial crown required laboratory modification of its shape and shade before the definitive restoration was accepted clinically and cemented. At the subsequent follow-up, only a minimal occlusal adjustment was required.

Later clinical images showed healthy-appearing and stable peri-implant soft tissues. Long-term supportive care was documented through May 2026, with stable clinical conditions and a six-month recall interval.


Conclusion


This case illustrates how the individual anatomy of the implant site can guide implant design selection. The combination of an intact buccal bone wall and dense palatal bone provided favorable conditions for the standard SDS tissue-level ceramic implant.

Immediate placement resulted in high primary stability and uneventful early healing, while careful prosthetic management contributed to the esthetic integration of the definitive restoration.

Could an oval or triangular implant also have been used in this case? The answer ultimately depends on the available bone, the anatomy of the extraction socket, and the desired prosthetic outcome.

Next month, we will conclude our esthetic series by comparing all three designs: triangular, oval, and standard SDS tissue-level ceramic implants.


Do you have an interesting clinical case of your own?


Have you treated an exciting or particularly challenging case with an SDS implant?

Then take part in our SDS Case Contest 2026 and share your case with us. We look forward to seeing your clinical approaches and treatment outcomes.




FAQs – SDS Standard Ceramic Implant Case

1. When can a standard tissue-level ceramic implant be considered in the anterior region?
In the presented case, an intact buccal bone wall and dense palatal bone provided favorable anatomical conditions for the round standard implant design. The available palatal bone could be used to achieve primary stability while minimizing pressure on the buccal bone.
2. Can a standard SDS tissue-level ceramic implant be placed immediately after extraction?
In this case, the compromised maxillary central incisor was extracted and an SDS 1.2_4614 zirconia implant was placed immediately into the extraction socket. High primary stability was achieved, followed by uneventful early healing.
3. Why was the implant positioned more palatally?
The palatal position allowed the dense palatal bone to contribute to primary stability while avoiding unnecessary compression of the buccal bone, which is particularly relevant in the esthetic zone.
4. Could an oval or triangular implant have been used instead?
Implant design should be selected according to the individual anatomy of the site. The available bone, extraction socket anatomy, and planned prosthetic restoration all need to be considered when choosing between a standard, oval, or triangular design.



Note: The information provided is intended for educational purposes only and does not replace clinical judgment. Treatment decisions should be based on individual patient assessment and applicable clinical guidelines.

Disclaimer: This article describes a single clinical case. The observations are specific to this patient and cannot be generalised; individual results may vary. Treatment decisions are the sole responsibility of the treating clinician. Always follow the instructions for use of all products used. Product availability, indications and approvals may differ by country.




Surgeon

Moritz Kneer
Moritz Kneer
Lead Surgeon, Sports Dentist at SWISS BIOHEALTH CLINIC, graduate of the University of Ulm, and practitioner of biological and metal-free dentistry according to the SWISS BIOHEALTH CONCEPT



Scientific Review & Medical Validation

Prof. Dr. med. dent. E. Schnurr
Prof. Dr. med. dent. E. Schnurr (Scientific Advisor, SDS)
Provides scientific guidance for SWISS DENTAL SOLUTIONS. She researches the oral microbiome, biofilm infections, and their impact on overall health: from clinical research and data analysis to drug development.





Do you have any questions or would you like more information? Feel free to contact us directly using the contact form below.


More posts from this category

don't miss anything

SDS Newsletter